Please use this identifier to cite or link to this item:
https://rda.sliit.lk/handle/123456789/1103
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Abeygunawardhana, P. K. W | - |
dc.contributor.author | Qi, W | - |
dc.contributor.author | Kojima, D | - |
dc.contributor.author | Suzuki, S | - |
dc.contributor.author | Nishiyama, A | - |
dc.contributor.author | Ishimaru, I | - |
dc.date.accessioned | 2022-02-10T09:44:05Z | - |
dc.date.available | 2022-02-10T09:44:05Z | - |
dc.date.issued | 2013-02-25 | - |
dc.identifier.citation | Pradeep K. W. Abeygunawardhana, Wei Qi, Daisuke Kojima, Satoru Suzuki, Akira Nishiyama, Ichirou Ishimaru, "Novel algorithm for background correction of the quantitative spectroscopic tomography of the biogenic-substances," Proc. SPIE 8591, Optical Diagnostics and Sensing XIII: Toward Point-of-Care Diagnostics, 85910O (25 February 2013); https://doi.org/10.1117/12.2003402 | en_US |
dc.identifier.uri | http://rda.sliit.lk/handle/123456789/1103 | - |
dc.description.abstract | The non-invasive blood sugar sensor by using imaging-type 2-dimensional Fourier spectroscopy is to be realized in this work. The spectroscopic imaging, that observes the biological tissue by the dark-field image, can measure the biogenic substance quantitatively such as the glucose concentration. For the quantitative analysis with high accuracy, the correction of the background such as the light-source fluctuation and the phase-shift uncertainty is inevitable issue. Thus, the quantitative band-pass plate on which the grating is locally formed has been already proposed by [1]. In that paper, the diffractive light, whose diffraction angle depends on the wavelength, has been used as the reference light. Object lens is used to narrow down the reference light and narrowed band pass diffraction light is obtained. The changes of imaging intensities with interference phenomenon on whole area of the observation image can be confirmed using the quantitative band pass filter. This paper proposed background correction method of the interferogram in spectroscopic tomography. Correction algorithm mainly contained two parts as light source fluctuation error correction and phase shift error correction. | en_US |
dc.language.iso | en | en_US |
dc.publisher | International Society for Optics and Photonics | en_US |
dc.relation.ispartofseries | Optical Diagnostics and Sensing XIII: Toward Point-of-Care Diagnostics;Vol 8591 Pages 85910O | - |
dc.subject | Novel algorithm | en_US |
dc.subject | background correction | en_US |
dc.subject | quantitative spectroscopic | en_US |
dc.subject | spectroscopic tomography | en_US |
dc.subject | biogenic-substances | en_US |
dc.title | Novel algorithm for background correction of the quantitative spectroscopic tomography of the biogenic-substances | en_US |
dc.type | Article | en_US |
dc.identifier.doi | https://doi.org/10.1117/12.2003402 | en_US |
Appears in Collections: | Research Papers - Dept of Computer Systems Engineering Research Papers - Open Access Research Research Papers - SLIIT Staff Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
85910O.pdf | 1.19 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.