Please use this identifier to cite or link to this item: https://rda.sliit.lk/handle/123456789/1175
Title: Precision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomography
Authors: Abeygunawardhana, P. K. W
Suzuki, S
Ishimaru, I
Nishiyama, A
Keywords: Spectroscopic measurement is being widely used for non-invasive blood sugar measurement in recent past. Imaging type two-dimensional spectroscopic tomography has been designed using wave front division interferometer. Variable phase filter, which has fixed mirror and movable mirror, has been used to introduce the phase shift between rays. Capability of measuring biogenic substances using this method has been proved. Variable phase filter has a piezoelectric actuator which has the stroke of 30μm. However, it is not enough for mid-infrared application. Smooth Impact drive mechanism with longer stroke was used here. However, smooth control is challengeable. This paper proposed the control of SIDM using PID control and Pseudo inverse differentiation. Proposed controller implemented and experiment result proved the effectiveness of proposed method.
Imaging type two-dimensional spectroscopic tomography
PID control
Pseudo-differentiation
variable phase filter
Issue Date: 1-Sep-2013
Publisher: IEEE
Citation: P. Abeygunawardhana, S. Suzuki, I. Ishimaru and A. Nishiyama, "Precision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomography," in 2013 International Conference on Social Computing (SocialCom), Alexandria, VA, USA, 2013 pp. 858-863. doi: 10.1109/SocialCom.2013.129 keywords: {} url: https://doi.ieeecomputersociety.org/10.1109/SocialCom.2013.129
Series/Report no.: 2013 International Conference on Social Computing (SocialCom);Pages 858-863
Abstract: Spectroscopic measurement is being widely used for non-invasive blood sugar measurement in recent past. Imaging type two-dimensional spectroscopic tomography has been designed using wave front division interferometer. Variable phase filter, which has fixed mirror and movable mirror, has been used to introduce the phase shift between rays. Capability of measuring biogenic substances using this method has been proved. Variable phase filter has a piezoelectric actuator which has the stroke of 30μm. However, it is not enough for mid-infrared application. Smooth Impact drive mechanism with longer stroke was used here. However, smooth control is challengeable. This paper proposed the control of SIDM using PID control and Pseudo inverse differentiation. Proposed controller implemented and experiment result proved the effectiveness of proposed method.
URI: http://rda.sliit.lk/handle/123456789/1175
Appears in Collections:Research Papers - Dept of Computer Systems Engineering
Research Papers - SLIIT Staff Publications

Files in This Item:
File Description SizeFormat 
Precision_Controlled_Variable_Phase_Filter_for_Imaging_Type_Two-Dimensional_Spectroscopic_Tomography.pdf
  Until 2050-12-31
1.61 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.