Repository logo
Repository
Browse
SLIIT Journals
OPAC
Log In
  1. Home
  2. Browse by Author

Browsing by Author "Fonseka, H. A"

Filter results by typing the first few letters
Now showing 1 - 3 of 3
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    PublicationEmbargo
    Analysis and interpretation of dissolved gases in transformer oil: A case study
    (IEEE, 2012-09-23) Hettiwatte, S. N; Fonseka, H. A
    Condition monitoring plays a vital role in any asset management plan. Dissolved gas analysis is a routine test carried out on power transformers to monitor their condition. Four power transformers selected from a repository of power transformers due to their dissolved gas levels exceeding the normal levels are analyzed using the Key Gas Method, the Roger's Ratio Method and the Duval Triangle Method to diagnose any faults. The results show that for some transformers all three diagnosis methods agree on the type of fault, whilst for others it is not so straightforward in diagnoses. In this study, the condition of each power transformer is predicted using the above methods.
  • Thumbnail Image
    PublicationOpen Access
    Condition monitoring in New Zealand power transformers
    (nternational Conference on Condition Monitoring and Diagnosis (CMD2010), 2010) Hettiwatte, S. N; Fonseka, H. A
    — Transpower owns and operates New Zealand’s high voltage electricity grid which includes approximately 725 in service power transformers [1]. Presently, condition monitoring of these units is routinely carried out by oil testing (moisture, acidity and dielectric breakdown) and using dissolved gas analysis (DGA), (every year), and winding resistance, insulation resistance, and bushing power factor tests (every four years). However, since the average age of a power transformer in New Zealand is nearly 40 years [1], it is considered that online condition monitoring of important transformers or transformers that have known issues is carried out to identify any incipient faults. The online condition monitoring in existing power transformers is hoped to minimize the risk of sudden failures and thereby prolong the in service life. It is equally important to decide on what to monitor in a power transformer and how to monitor, and these are also governed by the budgetary constraints. Transpower is in the process of acquiring online condition monitoring units for some of the new large power transformers it plans to purchase and will also retrofit such units to some old transformers as required. This paper presents the condition monitoring techniques currently used by Transpower on power transformers, and the online condition monitoring techniques for new and existing power transformers.
  • Thumbnail Image
    PublicationOpen Access
    A novel visualisation technique for dissolved gas analysis datasets–A case study
    (Australasian Universities Power Engineering Conference, 2013) Fonseka, H. A; Hettiwatte, S. N; Lee, G
    Dissolved gas analysis is the most widely used diagnostic test in power transformers. There are established methods used in industry for interpreting DGA results. Among these are the IEEE Key Gas Method, Rogers’ Ratios and the Duval Triangle. However, collectively these methods can lead to conflicting results or unclassifiable measurements. This paper presents a visualization technique for interpreting DGA results to mitigate these effects, based on Kernel Principal Component Analysis. DGA measurements from more than 200 power transformers are used to validate the approach.

Copyright 2025 © SLIIT. All Rights Reserved.

  • Privacy policy
  • End User Agreement
  • Send Feedback