Repository logo
Repository
Browse
SLIIT Journals
OPAC
Log In
  1. Home
  2. Browse by Author

Browsing by Author "Hiramatsu, H"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    PublicationOpen Access
    Proposal of AAA-battery-size one-shot ATR Fourier spectroscopic imager for on-site analysis: Simultaneous measurement of multi-components with high accuracy
    (International Society for Optics and Photonics, 2015-03-12) Hosono, S; Qi, W; Sato, S; Suzuki, Y; Fujiwara, M; Hiramatsu, H; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    For simultaneous measurement of multi-components on-site like factories, the ultra-compact (diameter: 9[mm], length: 45[mm], weight: 200[g]) one-shot ATR (Attenuated Total Reflection) Fourier spectroscopic imager was proposed. Because the proposed one-shot Fourier spectroscopic imaging is based on spatial-phase-shift interferometer, interferograms could be obtained with simple optical configurations. We introduced the transmission-type relativeinclined phase-shifter, that was constructed with a cuboid prism and a wedge prism, onto the optical Fourier transform plane of infinity corrected optical systems. And also, small light-sources and cameras in the mid-infrared light region, whose size are several millimeter on a side, are essential components for the ultra-compact spectroscopic configuration. We selected the Graphite light source (light source area: 1.7×1.7[mm], maker: Hawkeye technologies) whose radiation factor was high. Fortunately, in these days we could apply the cost-effective 2-dimensional light receiving device for smartphone (e.g. product name: LEPTON, maker: FLIR, price: around 400USD). In the case of alcoholic drinks factory, conventionally workers measure glucose and ethanol concentrations by bringing liquid solution back to laboratories every day. The high portable spectroscopy will make it possible to measure multi-components simultaneously on manufacturing scene. But we found experimentally that absorption spectrum of glucose and water and ethanol were overlapped each other in near infrared light region. But for mid-infrared light region, we could distinguish specific absorption peaks of glucose (@10.5[μm]) and ethanol (@11.5[μm]) independently from water absorption. We obtained standard curve between absorption (@9.6[μm]) and ethanol concentration with high correlation coefficient 0.98 successfully by ATR imaging-type 2-dimensional Fourier spectroscopy (wavelength resolution: 0.057[μm]) with the graphite light source (maker: Hawkeye technologies, type: IR-75).
  • Thumbnail Image
    PublicationOpen Access
    Wide-field spectroscopic imaging of biological-substance distributions on entire faces by measuring middle infrared lights emitted from human bodies itself
    (SPIE, 2014-02-28) Suzuki, Y; Qi, W; Fujiwara, M; Hiramatsu, H; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    We are aiming at the realization of the measurement technology for the biological-substance distributions, such as sebum, on entire faces at the daily-life environment. We proposed the imaging-type 2-dimensional Fourier spectroscopy [1] that is the palmtop-size portable measurement apparatus and has the strong robustness for mechanical vibrations. And the proposed method can measure the wide-field 2-dimensional middle-infrared spectroscopic-imaging of radiation lights emitted from human bodies itself without light sources. In the proposed method, we install the phase-shifter, that can give an arbitrary phase difference for the half-flux of objective beams, at the optical Fourier transform plane of the infinity corrected optical system. The near-common-path interferometer that is a phase-shift interferometer between objective beams can be realized. In this proposed method, the emitted rays from each single-bright-point on measurement surfaces can interfere with each other. Thus, even if the middle infrared-lights from human bodies are the spatially incoherent light, we can acquire the interferograms at each pixel on an imaging array-device in accordance with the amount of phase shift as the 2-dimensional image-intensity changes. We demonstrated the feasibility of the middle infrared spectroscopic imaging of whole human faces without active illuminations.

Copyright 2025 © SLIIT. All Rights Reserved.

  • Privacy policy
  • End User Agreement
  • Send Feedback