Publish in Scimago's Q1 and Q2 Journals

Permanent URI for this communityhttps://rda.sliit.lk/handle/123456789/4196

Browse

Search Results

Now showing 1 - 5 of 5
  • Thumbnail Image
    PublicationEmbargo
    OcupHI: knowledge-driven colorimetric interpretation framework for high-precision real-time ocular pH diagnostics
    (Springer Nature, 2026-08-12) Kahandawala, B, S; Sandaruwan, H. H. P. B; Liyanage, P; Dassanayake, R.S; Costha, N.P; Liyanage, R.N; Wijenayake, U; Wijesinghe, R.E; Silva, B.N; Manatunga, D.C
    Ocular injuries due to chemical spills pose a substantial concern, representing 10–22% of all ocular trauma. Although precise detection of ocular pH is crucial for determining the optimal medical treatment, many existing methods remain invasive, biased, or insufficiently precise. Reliance on subjective visual assessment of subtle color differences limits the objectivity and hinders high-throughput analysis. Therefore, an advanced colorimetric knowledge-driven ocular pH detection method was developed using a biosensor (OcupHI) based on a Clitoria ternatea (Butterfly Pea) anthocyanin sensing agent. The proposed work delivers fast, high-precision, and easily measurable pH prediction across clinically relevant ranges, while supporting real-time decision support for eye physicians. The pH range from 1 to 12 was tested and compared with six different anthocyanin concentrations: 5, 10, 20, 30, 40, and 50 ppm, and five different machine learning models, namely, Decision Tree (DT), K-Nearest Neighbors (KNN), Random Forest (RF), Extreme Gradient Boosting (XGBoost), and Support Vector Machines (SVM). The results revealed that the 40 ppm anthocyanin concentration trained with the XGBoost model produced the most accurate ocular pH values, achieving superior performance with an overall accuracy of 96%, a significantly higher F1-score for early detection. Experimental validation clearly demonstrates strong predictive accuracy, robustness, and interpretability, highlighting the potential for next-generation ocular diagnostics. Further research findings support Sustainable Development Goal (SDG) 3 – good health and well-being through a real-time ocular pH monitoring kit, and SDG 12 – responsible consumption and production by optimizing the use of the natural colorant anthocyanin for sensor development.
  • Thumbnail Image
    PublicationEmbargo
    Bi-directional long short-term memory based ensemble deep learning framework for non-linear steam turbine power forecasting: a biomass fuelled case study
    (Elsevier Ltd, 2026-04-10) Perera, H; Jayasekara, S; Wijesinghe, R.E; Silva, B. N; Cha, H
    In palm oil manufacturing, steam turbines powered by biomass fuel are central to energy generation. However, fluctuating load demands and temporal variations lead to inefficiencies, while limited and variable supply of biomass waste constrains boiler feed flexibility. Current index-based boiler feeding methods overlook actual load demands and waste availability, resulting in significant energy wastage. This study presents a novel ensemble deep learning model combining Bidirectional Long Short-Term Memory (Bi-LSTM) and Gated Recurrent Units (GRU) with Attention Layers, trained on an eight-year operational dataset with structured preprocessing and feature selection, to forecast steam turbine power generation. The model captures complex non-linear temporal patterns more effectively than conventional and standalone ML models, achieving a Root Mean Square Error (RMSE) of 0.0684, Mean Absolute Error (MAE) of 0.0414, and an R-squared (R2) value of 0.9832, which outperformed eight benchmark models by approximately 25% in prediction accuracy. Additionally, the framework incorporates operational parameters such as kVA, total energy, and Fresh Fruit Bunch (FFB) production to dynamically optimise biomass feed rates, balancing energy output with resource availability. This approach minimises energy wastage, reduces grid reliance, and promotes both sustainability and profitability.
  • Thumbnail Image
    PublicationEmbargo
    High-resolution optical imaging for sustainable fish freshness and safety assessment
    (Elsevier GmbH, 2026-04) Madhubhashini, M. N; Kahandawala, B.S; Sandaruwan, H.H.P. B; Silva, B.N; Wijenayake, U; Wijesinghe, R.E
    Fish freshness evaluation is crucial to ensure consumer safety, and rapid assessment is essential for effective and accurate quality control. To overcome the limitations of the gold standards, such as lack of structural depth information, high-time consumption, and labor-intensiveness, high-resolution Optical Coherence Tomography (OCT) was employed for real-time monitoring of fish freshness non-invasively. Microstructural changes of eye and skin of Indian Anchovies ( Stolephorus indicus ) specimens were considered as the main freshness parameters during refrigeration storage. Both eye and skin tissues exhibited decreased internal scattering, loss of clarity, boundary weakening, and gradual structural degradations through the OCT observations. The quantitatively assessed variance intensity, entropy, energy, and edge density clearly revealed the internal tissue disruption over storage time due to protein denaturation, oxidative damage, and fluid imbalance. The findings of this study indicate that OCT shows an insightful correlation with microbiological and biochemical spoilage processes, enabling the advanced identification of subtle microstructural changes in fish skin and eye, even at a prior stage of deterioration. Such capability offers an objective and rapid freshness evaluation approach that could greatly benefit supply chain management and post-harvest seafood quality monitoring.
  • Thumbnail Image
    PublicationOpen Access
    Three-Dimensional Assessment of Dental Enamel Microcrack Progression After Orthodontic Bracket Debonding Using Optical Coherence Tomography
    (Multidisciplinary Digital Publishing Institute (MDPI), 2025-01) Saleah, S.A; Hamdan, A.H; Seong, D; Ravichandran, N. K; Wijesinghe, R.E; Han, S; Kim, J; Jeon, M; Park, H. S
    The current study aimed to quantify the length progression of enamel microcracks (EMCs) after debonding metal and ceramic brackets, implementing OCT as a diagnostic tool. The secondary objectives included a three-dimensional assessment of EMC width and depth and the formation of new EMCs. OCT imaging was performed on 16 extracted human premolars before bonding and after debonding. Debonding was conducted with a universal Instron machine, with ARI values recorded. Additionally, 2D and 3D OCT images were employed to detect EMC formation and progression. Enface images quantified the length, width, and number of EMCs, and the length and width were analyzed using Image J (1.54f) and MATLAB (R2014b), respectively. Sagittal cross-sectional images were used for EMC depth analysis. A paired t-test showed significant differences in the length, width, and number of EMCs after debonding (p-value < 0.05), while the Wilcoxon non-parametric test indicated significant EMC depth changes (p-value < 0.05). No significant results were identified for the EMC number in ceramic brackets and EMC depth in metal brackets. Three-dimensional OCT imaging monitored existing EMCs at higher risk of progression and detected new EMCs following orthodontic bracket debonding. This study provides novel insights into EMC progression regarding the length, width, depth, and number after debonding.
  • Thumbnail Image
    PublicationOpen Access
    Real-Time Coordinate Estimation for SCARA Robots in PCB Repair Using Vision and Laser Triangulation
    (Multidisciplinary Digital Publishing Institute (MDPI), 2025-04-07) Sanjeewa, N; Wathudura, V. M; Kahatapitiya, N. S; Silva, B. N; Subasinghage, K.; Wijesinghe, R.E
    The Printed Circuit Board (PCB) manufacturing industry is a rapidly expanding sector, fueled by advanced technologies and precision-oriented production processes. The placement of Surface-Mount Device (SMD) components in PCB assembly is efficiently automated using robots and design software-generated coordinate files; however, the PCB repair process remains significantly more complex and challenging. Repairing faulty PCBs, particularly replacing defective SMD components, requires high precision and significant manual expertise, making automated solutions both rare and difficult to implement. This study introduces a novel real-time machine vision-based coordinate estimation system designed for estimating the coordinates of SMD components during soldering or desoldering tasks. The system was specifically designed for Selective Compliance Articulated Robot Arm (SCARA) robots to overcome the challenges of repairing miniature PCB components. The proposed system integrates Image-Based Visual Servoing (IBVS) for precise X and Y coordinate estimation and a simplified laser triangulation method for Z-axis depth estimation. The system demonstrated accuracy rates of 98% for X and Y axes and 99% for the Z axis, coupled with high operational speed. The developed solution highlights the potential for automating PCB repair processes by enabling SCARA robots to execute precise picking and placement tasks. When equipped with a hot-air gun as the end-effector, the system could enable automated soldering and desoldering, effectively replacing faulty SMD components without human intervention. This advancement has the potential to bridge a critical gap in the PCB repair industry, improving efficiency and reducing dependence on manual expertise.