Scopus Index Publications
Permanent URI for this communityhttps://rda.sliit.lk/handle/123456789/2162
This collection consists of all Scopus-indexed publications produced by SLIIT researchers. Scopus is recognized worldwide as a leading and reputable academic indexing database.
Browse
3 results
Search Results
Publication Open Access Anthocyanin (ATH)-incorporating polyvinylpyrrolidone-ethyl cellulose-(2-hydroxypropyl)-β-cyclodextrin (PVP–EC–BCD) nanofiber-based pH sensor for ocular pH detection during accidental chemical spills(Royal Society of Chemistry, 2026-02-03) Sandaruwan, B; Liyanage, R; Costha, P; Dassanayake, R.S; Wijesinghe, R.E; Herath H.M.L.P.B.; Nalin de S.K.M; de Silva, R.M; Rajapaksha, S.M; Wijenayake, U; Manatunga, D.CThe existing ocular pH detection methods encounter numerous limitations, including low accuracy, poor sensitivity across a wide pH range, and patient discomfort, highlighting the need for innovative approaches. A novel biosensor for ocular pH detection has been developed to assess ocular health and chemical injuries in clinical settings. This study uses the pH-sensitive properties of anthocyanins (ATHs), natural pigments extracted from butterfly pea flowers, to develop a novel pH-responsive nanofiber mat. ATHs are integrated into a polymer blend containing polyvinylpyrrolidone (PVP), ethyl cellulose (EC), and (2-hydroxypropyl)-β-cyclodextrin (BCD) to fabricate electrospun nanofibers. The acquired characterization, employing scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and thermogravimetric analysis (TGA), confirmed the successful fabrication of the ATH-infused nanofibers with a mean diameter ranging from 121 to 396 nm. Four formulations were tested: PVP:EC:BCD:ATH (18 ppm), PVP:EC:BCD:ATH (25 ppm), PVP:EC:BCD:ATH (35 ppm), and PVP:EC:BCD:ATH (50 ppm). Among them, the 50 ppm ATH-incorporating nanofiber mat exhibited the best performance in terms of color clarity, response time, and pH sensitivity. The fabricated 50 ppm ATH incorporating nanofiber mat demonstrated a rapid pH response time of less than 5 seconds (s) while exhibiting a color variation from pink to blue to green across the pH range of 1 to 12, providing a rapid and accurate method for visual pH detection. Based on the color performance of the 50 ppm ATH-incorporating system, a standardized color reference chart was developed to serve as a practical and visual guide for estimating pH levels in clinical applications. Zebrafish toxicity assays were conducted further to validate the safety and biocompatibility of the developed sensor, revealing no significant toxic effects across the range of ATH concentrations.Publication Open Access Anthocyanin (ATH)-incorporating polyvinylpyrrolidone-ethyl cellulose-(2-hydroxypropyl)-β-cyclodextrin (PVP–EC–BCD) nanofiber-based pH sensor for ocular pH detection during accidental chemical spills(Royal Society of Chemistry, 2026-02-03) Sandaruwan, B; Liyanage, R; Costha, P; Dassanayake, R.S; Wijesinghe, R.E; Herath H.M.L.P.B; Nalin de S.K.M; de Silva, R.M; Rajapaksha, S.M; Wijenayake, UThe existing ocular pH detection methods encounter numerous limitations, including low accuracy, poor sensitivity across a wide pH range, and patient discomfort, highlighting the need for innovative approaches. A novel biosensor for ocular pH detection has been developed to assess ocular health and chemical injuries in clinical settings. This study uses the pH-sensitive properties of anthocyanins (ATHs), natural pigments extracted from butterfly pea flowers, to develop a novel pH-responsive nanofiber mat. ATHs are integrated into a polymer blend containing polyvinylpyrrolidone (PVP), ethyl cellulose (EC), and (2-hydroxypropyl)-β-cyclodextrin (BCD) to fabricate electrospun nanofibers. The acquired characterization, employing scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and thermogravimetric analysis (TGA), confirmed the successful fabrication of the ATH-infused nanofibers with a mean diameter ranging from 121 to 396 nm. Four formulations were tested: PVP:EC:BCD:ATH (18 ppm), PVP:EC:BCD:ATH (25 ppm), PVP:EC:BCD:ATH (35 ppm), and PVP:EC:BCD:ATH (50 ppm). Among them, the 50 ppm ATH-incorporating nanofiber mat exhibited the best performance in terms of color clarity, response time, and pH sensitivity. The fabricated 50 ppm ATH incorporating nanofiber mat demonstrated a rapid pH response time of less than 5 seconds (s) while exhibiting a color variation from pink to blue to green across the pH range of 1 to 12, providing a rapid and accurate method for visual pH detection. Based on the color performance of the 50 ppm ATH-incorporating system, a standardized color reference chart was developed to serve as a practical and visual guide for estimating pH levels in clinical applications. Zebrafish toxicity assays were conducted further to validate the safety and biocompatibility of the developed sensor, revealing no significant toxic effects across the range of ATH concentrations.Publication Embargo UveaTrack: Uveitis Eye Disease Prediction and Detection with Vision Function Calculation and Risk Analysis Publisher: IEEE Cite This PDF(Institute of Electrical and Electronics Engineers, 2022-10-15) Perera, B. D. K; Wickramarathna, W.A.A.I.; Chandrasiri, S; Wanniarachchi, W.A.P.W; Dilshani, S.H.N; Pemadasa, NUveitis is an inflammatory infection that affects uvea tissue, the middle layer of the eyewall. It can result in swelling or damage to the eye and lead to vision impairments or blindness. Most Uveitis symptoms are associated with many other diseases localized to the eye. Thus, it is hard to determine the responsible symptoms for uveitis. Consequently, early detection of this disease can prevent a perilous situation in the future. The initial motivation behind the design of this mobile application is to help accurately diagnose uveitis with minimal time and effort and thereby minimize the shortage of human specialists in this field. The 'UveaTrack' is a hybrid mobile application that enables the keep tracking of uveitis eye illness and uses machine learning (ML) algorithms, deep learning (DL) architectures, and image processing techniques for developing the system. The 'UveaTrack' application could be able to achieve an average accuracy of more than 85% and had produced overall better results. Furthermore, the 'UveaTrack' application can use as a valuable instructional tool for freshly graduated clinicians, supporting their work with patients and assisting them in making diagnostics conclusions.
