Publication:
Precision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomography

dc.contributor.authorAbeygunawardhana, P. K. W
dc.contributor.authorSuzuki, S
dc.contributor.authorIshimaru, I
dc.contributor.authorNishiyama, A
dc.date.accessioned2022-02-15T04:50:58Z
dc.date.available2022-02-15T04:50:58Z
dc.date.issued2013-09-01
dc.description.abstractSpectroscopic measurement is being widely used for non-invasive blood sugar measurement in recent past. Imaging type two-dimensional spectroscopic tomography has been designed using wave front division interferometer. Variable phase filter, which has fixed mirror and movable mirror, has been used to introduce the phase shift between rays. Capability of measuring biogenic substances using this method has been proved. Variable phase filter has a piezoelectric actuator which has the stroke of 30μm. However, it is not enough for mid-infrared application. Smooth Impact drive mechanism with longer stroke was used here. However, smooth control is challengeable. This paper proposed the control of SIDM using PID control and Pseudo inverse differentiation. Proposed controller implemented and experiment result proved the effectiveness of proposed method.en_US
dc.identifier.citationP. Abeygunawardhana, S. Suzuki, I. Ishimaru and A. Nishiyama, "Precision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomography," in 2013 International Conference on Social Computing (SocialCom), Alexandria, VA, USA, 2013 pp. 858-863. doi: 10.1109/SocialCom.2013.129 keywords: {} url: https://doi.ieeecomputersociety.org/10.1109/SocialCom.2013.129en_US
dc.identifier.doi10.1109/SocialCom.2013.129en_US
dc.identifier.urihttps://rda.sliit.lk/handle/123456789/1175
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartofseries2013 International Conference on Social Computing (SocialCom);Pages 858-863
dc.subjectSpectroscopic measurement is being widely used for non-invasive blood sugar measurement in recent past. Imaging type two-dimensional spectroscopic tomography has been designed using wave front division interferometer. Variable phase filter, which has fixed mirror and movable mirror, has been used to introduce the phase shift between rays. Capability of measuring biogenic substances using this method has been proved. Variable phase filter has a piezoelectric actuator which has the stroke of 30μm. However, it is not enough for mid-infrared application. Smooth Impact drive mechanism with longer stroke was used here. However, smooth control is challengeable. This paper proposed the control of SIDM using PID control and Pseudo inverse differentiation. Proposed controller implemented and experiment result proved the effectiveness of proposed method.en_US
dc.subjectImaging type two-dimensional spectroscopic tomographyen_US
dc.subjectPID controlen_US
dc.subjectPseudo-differentiationen_US
dc.subjectvariable phase filteren_US
dc.titlePrecision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomographyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Precision_Controlled_Variable_Phase_Filter_for_Imaging_Type_Two-Dimensional_Spectroscopic_Tomography.pdf
Size:
1.57 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: