Publication:
Novel algorithm for background correction of the quantitative spectroscopic tomography of the biogenic-substances

dc.contributor.authorAbeygunawardhana, P. K. W
dc.contributor.authorQi, W
dc.contributor.authorKojima, D
dc.contributor.authorSuzuki, S
dc.contributor.authorNishiyama, A
dc.contributor.authorIshimaru, I
dc.date.accessioned2022-02-10T09:44:05Z
dc.date.available2022-02-10T09:44:05Z
dc.date.issued2013-02-25
dc.description.abstractThe non-invasive blood sugar sensor by using imaging-type 2-dimensional Fourier spectroscopy is to be realized in this work. The spectroscopic imaging, that observes the biological tissue by the dark-field image, can measure the biogenic substance quantitatively such as the glucose concentration. For the quantitative analysis with high accuracy, the correction of the background such as the light-source fluctuation and the phase-shift uncertainty is inevitable issue. Thus, the quantitative band-pass plate on which the grating is locally formed has been already proposed by [1]. In that paper, the diffractive light, whose diffraction angle depends on the wavelength, has been used as the reference light. Object lens is used to narrow down the reference light and narrowed band pass diffraction light is obtained. The changes of imaging intensities with interference phenomenon on whole area of the observation image can be confirmed using the quantitative band pass filter. This paper proposed background correction method of the interferogram in spectroscopic tomography. Correction algorithm mainly contained two parts as light source fluctuation error correction and phase shift error correction.en_US
dc.identifier.citationPradeep K. W. Abeygunawardhana, Wei Qi, Daisuke Kojima, Satoru Suzuki, Akira Nishiyama, Ichirou Ishimaru, "Novel algorithm for background correction of the quantitative spectroscopic tomography of the biogenic-substances," Proc. SPIE 8591, Optical Diagnostics and Sensing XIII: Toward Point-of-Care Diagnostics, 85910O (25 February 2013); https://doi.org/10.1117/12.2003402en_US
dc.identifier.doihttps://doi.org/10.1117/12.2003402en_US
dc.identifier.urihttps://rda.sliit.lk/handle/123456789/1103
dc.language.isoenen_US
dc.publisherInternational Society for Optics and Photonicsen_US
dc.relation.ispartofseriesOptical Diagnostics and Sensing XIII: Toward Point-of-Care Diagnostics;Vol 8591 Pages 85910O
dc.subjectNovel algorithmen_US
dc.subjectbackground correctionen_US
dc.subjectquantitative spectroscopicen_US
dc.subjectspectroscopic tomographyen_US
dc.subjectbiogenic-substancesen_US
dc.titleNovel algorithm for background correction of the quantitative spectroscopic tomography of the biogenic-substancesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
85910O.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: