Single board computer and adapted 3D-printed case-based low cost and compact optical coherence tomography

dc.contributor.authorSeong, D
dc.contributor.authorHan, S
dc.contributor.authorKim, Y
dc.contributor.authorHong, J
dc.contributor.authorWijhesinghe, R. E
dc.contributor.authorJeon, M
dc.contributor.authorKim, J
dc.date.accessioned2026-03-21T08:54:53Z
dc.date.issued2025
dc.description.abstractOptical coherence tomography (OCT) is a non-invasive, label-free imaging method based on high-resolution interferometric optics that allows real-time visualization of morphological structures and depth-resolved images. The high cost of most commercially available OCT systems limits their widespread use, especially in resource-poor settings. Miniaturization of OCT devices therefore reduces not only size but also cost and has the potential to open new markets for this technology. In this study, we developed a small, portable 3D printed OCT system (SBC-OCT) based on a single-board computer. To reduce the cost to configure the system, the whole case of SBC-OCT is made with 3D-printed architecture. Using an area camera to avoid thermally induced alignment distortions in the spectrometer during system operation, the spectrometer is temperature insensitive, requires no hardware changes or additional components, and requires minimal computational effort. An applied automatic signal correction method was developed. The smaller size, lighter weight, and lower cost of SBC-OCT highlight its significant relevance in medical, industrial, and security applications, showcasing its potential for broad adoption.
dc.identifier.doiDOI: 10.1117/12.3041806
dc.identifier.isbn978-151068362-4
dc.identifier.urihttps://rda.sliit.lk/handle/123456789/4881
dc.language.isoen
dc.publisherSPIE
dc.relation.ispartofseriesProgress in Biomedical Optics and Imaging - Proceedings of SPIE; Volume 13307 Article number 1330707
dc.subjectAutomatic peak detection
dc.subjectCompact optical coherence tomography
dc.subjectLatte Panda single-board computer
dc.subjectTemperature-insensitive optical coherence tomography
dc.titleSingle board computer and adapted 3D-printed case-based low cost and compact optical coherence tomography
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Single board computer and adapted 3D-printed case-based low cost.pdf
Size:
695.29 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description: