Repository logo
Repository
Browse
SLIIT Journals
OPAC
Log In
  1. Home
  2. Browse by Author

Browsing by Author "Wada, K"

Filter results by typing the first few letters
Now showing 1 - 5 of 5
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    PublicationOpen Access
    Measurement of the mid-infrared Fourier spectroscopic imaging of whole human face by portable apparatus (size: 50* 50 mm, weight: 200 g)
    (International Society for Optics and Photonics, 2014-11-20) Qi, W; Suzuki, Y; Fujiwara, M; Saito, T; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    In the daily living space, measurement of the biological-substance distributions such as sebum can be realized by the proposed method of imaging-type 2-dimensional Fourier spectroscopy. This method has the strong robustness for mechanical vibrations. So, the spectrometer (size: 50*50mm, weight: 200g) can be produced without anti-vibration mechanism. Moreover, the phase shifter is a core part of the spectrometer, and it is constructed by the low-price bimorph type actuator which is depending on the vibration control of the piezoceramic in proposed method. It is appropriate as the actuator of the phase shifter from the evaluation results of the actuator straightness and position accuracy in the midinfrared region. As we know, the Fourier spectroscopy has a high light utilization efficiency. Therefore, the low price microbolometer can be used as the imaging sensor. So, the low-price (10,000 U.S. dollars), compact and high portability spectrometer can be produced. Furthermore, the much higher position accuracy in the short wavelength region is requested as we know, the phase shift correction method has been proposed. In this paper, high performance evaluations of the portable spectroscopy apparatus have been discussed by using the CO2 laser spectroscopy results in the midinfrared region. Then, the phase shift correction method was explained. At the end, we demonstrated the feasibility of the mid-infrared imaging of whole human faces without active illuminations.
  • Thumbnail Image
    PublicationOpen Access
    Proposal of AAA-battery-size one-shot ATR Fourier spectroscopic imager for on-site analysis: Simultaneous measurement of multi-components with high accuracy
    (International Society for Optics and Photonics, 2015-03-12) Hosono, S; Qi, W; Sato, S; Suzuki, Y; Fujiwara, M; Hiramatsu, H; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    For simultaneous measurement of multi-components on-site like factories, the ultra-compact (diameter: 9[mm], length: 45[mm], weight: 200[g]) one-shot ATR (Attenuated Total Reflection) Fourier spectroscopic imager was proposed. Because the proposed one-shot Fourier spectroscopic imaging is based on spatial-phase-shift interferometer, interferograms could be obtained with simple optical configurations. We introduced the transmission-type relativeinclined phase-shifter, that was constructed with a cuboid prism and a wedge prism, onto the optical Fourier transform plane of infinity corrected optical systems. And also, small light-sources and cameras in the mid-infrared light region, whose size are several millimeter on a side, are essential components for the ultra-compact spectroscopic configuration. We selected the Graphite light source (light source area: 1.7×1.7[mm], maker: Hawkeye technologies) whose radiation factor was high. Fortunately, in these days we could apply the cost-effective 2-dimensional light receiving device for smartphone (e.g. product name: LEPTON, maker: FLIR, price: around 400USD). In the case of alcoholic drinks factory, conventionally workers measure glucose and ethanol concentrations by bringing liquid solution back to laboratories every day. The high portable spectroscopy will make it possible to measure multi-components simultaneously on manufacturing scene. But we found experimentally that absorption spectrum of glucose and water and ethanol were overlapped each other in near infrared light region. But for mid-infrared light region, we could distinguish specific absorption peaks of glucose (@10.5[μm]) and ethanol (@11.5[μm]) independently from water absorption. We obtained standard curve between absorption (@9.6[μm]) and ethanol concentration with high correlation coefficient 0.98 successfully by ATR imaging-type 2-dimensional Fourier spectroscopy (wavelength resolution: 0.057[μm]) with the graphite light source (maker: Hawkeye technologies, type: IR-75).
  • Thumbnail Image
    PublicationOpen Access
    Quantitative measurement of biological substances in daily-life environment with the little-finger-size one-shot spectroscopic tomography
    (International Society for Optics and Photonics, 2014-02-28) Ishida, A; Sato, S; Nakada, S; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    In daily-life environment, the quantitative measurement of biological substances, such as the blood glucose level in the human skin, is strongly required to realize the non-invasive healthcare apparatus. Fourier-spectroscopic-tomography of the little-finger-size with high time-resolution and with the strong robustness for mechanical vibrations is proposed. The proposed method is a kind of near-common-path interferometer with spatial phase-shift method. We install the transmission-type relative-inclined phase-shifter on the optical Fourier transform plane of the infinity corrected optical system. The phase shifter is constructed with the cuboid and wedge prisms to give the relative phase-shift spatially between each half-flux of the objective beams. The interferograms from each single-bright-point on an objective surface in a line are formed as fringe patterns on 2-dimensional imaging array devices. And because the proposed method is based on the imaging optics, only emitted rays from a focal plane can contribute forming of interferograms. Thus, the measurement plane can be limited onto the focal plane only. From the spectroscopic tomography, only at a localized vessel area in human skins, we can get the pinpointed near-infrared spectroscopic data. And we can expect the improvement of the determination precision, because a Fourier spectroscopic-character is acquired from multiple intensity data in accordance with amount of phase-shift. From the statistical point of view, the gradation of detector is improved with the square root of sample number, based on t-distribution. We constructed the statistical model to assure the determination accuracy, and demonstrated the feasibility of the glucose sensor using liquid cells.
  • Thumbnail Image
    PublicationOpen Access
    Spectrum correction considering light source fluctuation for non-invasive blood glucose sensing
    (SPIE, 2014-03-04) Suzuki, S; Ishida, A; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    The purpose of this study is to correct baseline shift in absorbance spectrums caused by light source fluctuation. To improve quantitative evaluation performance of blood glucose level, baseline shift is corrected by multiple scatter correction (MSC). Moreover, to increase the effect of the MSC, water vapor absorbance is subtracted, and relative glucose absorbance are calculated by dividing with hemoglobin absorbance at 1544 [cm-1]. In order to verify the effectiveness of the proposed spectrum correction method, light source fluctuation is simulated on the Fourier transform infrared spectroscopy (FT-IR), and we apply the proposed method to the spectrums measured by FT-IR. From the simulation results, the baseline shift was successfully reduced by proposed method.
  • Thumbnail Image
    PublicationOpen Access
    Wide-field spectroscopic imaging of biological-substance distributions on entire faces by measuring middle infrared lights emitted from human bodies itself
    (SPIE, 2014-02-28) Suzuki, Y; Qi, W; Fujiwara, M; Hiramatsu, H; Suzuki, S; Abeygunawardhana, P. K. W; Wada, K; Nishiyama, A; Ishimaru, I
    We are aiming at the realization of the measurement technology for the biological-substance distributions, such as sebum, on entire faces at the daily-life environment. We proposed the imaging-type 2-dimensional Fourier spectroscopy [1] that is the palmtop-size portable measurement apparatus and has the strong robustness for mechanical vibrations. And the proposed method can measure the wide-field 2-dimensional middle-infrared spectroscopic-imaging of radiation lights emitted from human bodies itself without light sources. In the proposed method, we install the phase-shifter, that can give an arbitrary phase difference for the half-flux of objective beams, at the optical Fourier transform plane of the infinity corrected optical system. The near-common-path interferometer that is a phase-shift interferometer between objective beams can be realized. In this proposed method, the emitted rays from each single-bright-point on measurement surfaces can interfere with each other. Thus, even if the middle infrared-lights from human bodies are the spatially incoherent light, we can acquire the interferograms at each pixel on an imaging array-device in accordance with the amount of phase shift as the 2-dimensional image-intensity changes. We demonstrated the feasibility of the middle infrared spectroscopic imaging of whole human faces without active illuminations.

Copyright 2025 © SLIIT. All Rights Reserved.

  • Privacy policy
  • End User Agreement
  • Send Feedback