dc.date.issued2025-01
dc.description.abstractElectrical distribution and communication cables cease to function for transmission when their length is insufficient, and it is considered as it approaches the end of their useful lives. Further, the disposal techniques are not eco-friendly. This study aimed to evaluate the feasibility of cement mortar systems with the inclusion of aluminium fibre extracted from electrical distribution cables. Two diameters of 1.35 mm and 1.70 mm and two lengths of 10 mm and 15 mm fibres were used while incorporating four volume ratios, particularly 0.5%, 1.0%, 1.5%, and 2.0% to evaluate the effect of the length, diameter and volume ratios. The compression test and density test were performed to study the behaviour of Metal Fibre Reinforced Mortar (MFRM) systems under both dry and wet states. Compared to conventional mortar, the ultimate compressive strength of MFRM systems was increased up to 39.4% in 1.5% of fibre addition under the 28-day dry state, where the 1.5% volume ratio showed the best performance under compressive loads. Strain at ultimate strength, modulus of elasticity and strain energy also showed improvements with the fibre inclusion up to 74.4%, 87.3%, and 106.6% respectively. Fibres with higher aspect ratios showed significant effectiveness among the aforementioned fibre variations. The overall results highlighted that the MFRM with 1.5% of fibres performed expertly with 15 mm length and 1.35 mm diameter under compression loads
dc.identifier.citationPerera, K.D.Y.G., Ahamed, Y.L.F., Somarathna, H.M.C.C. et al. Uniaxial compressive response of cement mortar with waste aluminium fibre sourced from electrical distribution cables. Multiscale and Multidiscip. Model. Exp. and Des. 8, 22 (2025). https://doi.org/10.1007/s41939-024-00622-0
dc.identifier.doihttps://doi.org/10.1007/s41939-024-00622-0
dc.identifier.issn25208160
dc.identifier.urihttps://rda.sliit.lk/handle/123456789/4715
dc.language.isoen
dc.publisherSpringer Science and Business Media
dc.relation.ispartofseriesMultiscale and Multidisciplinary Modeling, Experiments and Design ; Volume 8 Issue 1 Article number 22
dc.subjectCement mortar
dc.subjectCompressive strength
dc.subjectElectrical distribution cable waste fibre
dc.subjectMetal fibre reinforced mortar
dc.subjectSustainability
dc.subjectWaste management
dc.titleUniaxial compressive response of cement mortar with waste aluminium fibre sourced from electrical distribution cables
dc.typeArticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Uniaxial compressive response of cementmortar with waste.pdf
Size:
8.76 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description: